Canin+Corrosion Analysis allows the contractor to limit the maintenance tasks on reinforced concrete to the areas where it is really required. The Canin+ is the fastest instrument for corrosion analysis, offering a practical, cost-effective approach to the investigation of reinforced concrete. Corrosion analysis with the Canin+ allows a rapid, comprehensive test of the site and provides a fast assessment of locations where corrosion is likely to take place.

Two factors contribute to the improved performance of this concrete test hammer over its predecessors:

The Canin+ combines two methods for corrosion analysis of concrete in one instrument:

  • Corrosion analysis with the half–cell potential method:
    accurate field potential measurements aid in detecting active corrosion in rebars.
  • Corrosion analysis with the resistivity method:
    the instrument measures the specific electrical resistivity of concrete.

Product Variations:
Variations of the Canin+ are available depending on the accessories selected:

  • Best for corrosion analysis in areas below 20m2:
    Canin+ rod electrode for potential measurements
  • Best for corrosion analysis in areas between 20m2 and 100m2:
    Canin+ with 1–wheel electrode for potential measurements
  • Best for corrosion analysis in areas over 100m2:
    4–wheel electrode for potential measurements
  • Best for complementary diagnostics:
    Canin+ with Wenner probe for resistivity measurements
Features:
  • Immediate presentation of test area and reading directly on the instrument’s display
  • Total memory for 235’000 readings which can be stored
  • For further analysis, the Canin ProVista Software allows downloading, presenting and editing data measured by this instrument for corrosion analysis
Applications:
  • Rapid corrosion analysis of large areas using the 1– and the 4–Wheel Electrodes
  • Accurate location of areas of active rebar corrosion
  • Measurement of concrete resistivity to determine the probability of corrosion
Technical Data:
Corrosion Analysis with the Potential Measurement
Measurement range–999 mV to +340 mV
Resolution1 mV
Memorynon–volatile memory for up to 235’000 measurements stored in up to 71 object files
SoftwareCanin ProVista Software for downloading data and evaluation on PC
Battery operationsix LR 6 (AA) batteries, 1.5 V for up to 60 h (or 30 h with activated backlight)
Corrosion Analysis with the Resistance Measurement
Measurement range0 to 99 kOcm
Resolution1 kOcm
Memorynon-volatile memory for up to 5’800 measurements stored in up to 24 object files
Data transferby Windows Hyperterminal
Battery operationsix LR 6 (AA) batteries, 1.5 V for up to 40 h (or 20 h with activated backlight)
General
Impedance10 MO
Operating temperature0°to 60°C
Storage temperature–10°to 60° C
Display128 x 128 pixel graphic LCD with backlight
Data outputRS 232 interface, USB with adapter
Case dimensions580 x 480 x 210 mm (22.8 x 18.9 x 8.3 in.)
Weightnet. 10.6 kg (23.5 lbs); shipping 14 kg (31.1 lbs)
 

  Warranty:

  • Standard 2–year limited warranty on electronic parts of the Canin+ for corrosion analysis
  • Optional extended warranty periods up to 3 additional years

Product Brochure for Corrosion Analysis – Canin+


Home | Profile | Solutions | Products | Technical | Downloads | Enquiry | Gallery | Contact Us
Steel | Transportation | Structural | Geophysical | Industrial | Agriculture | Meteorology | Automotive | Mining
Copyright © Taisei International. All Rights Reserved.